|
|
TTA_AdminMode |
Corresponds to the Windows application object’s Console
Mode attribute. |
TTA_Appearance |
Corresponds to a character application object’s Border Style attribute. |
TTA_AppletHeight |
Corresponds to the application
object’s Window Size: Height attribute. |
TTA_AppletWidth |
Corresponds to the application object’s Window Size: Width attribute. |
TTA_ApplicationName |
The application
object’s fully qualified name. |
TTA_ApplicationPlacement |
Corresponds to the application object’s Window Type attribute. This variable can
have the value multiplewindows - client window management, awtwindow - independent window, kiosk -
kiosk, localx - local X server, and seamlesswindows - seamless window. |
TTA_Arguments |
Corresponds to the application
object’s Arguments For Command attribute. |
TTA_AudioQuality |
Corresponds to the Windows Audio Quality attribute on the Global
Settings -> Client Device tab in the Administration Console. This variable can have the
value low, medium, and high. |
TTA_Autowrap |
Corresponds to the character application object’s Line Wrapping attribute. |
TTA_BackgroundColor |
Corresponds to
the Background Color attribute for a 3270 or 5250 application object. |
TTA_ButtonLevels |
Corresponds to the
3270 or 5250 application object’s Displayed Soft Buttons attribute. This variable can have the
value 0 - No Buttons), 1 - 2 Rows, 2 - 4 Rows, 3
- 6 Rows, and 4 - 8 Rows. |
TTA_CachePassword |
Whether the user selected the Save
This Password? box when they supplied a user name and password for the application
server. |
TTA_CodePage |
Corresponds to the character application object’s Code Page attribute. This variable can have the
value 437, 850, 852, 860, 863, 865, 8859-1, 8859-2, Multinational, Mazovia, or CP852. |
TTA_ColorMap |
Corresponds
to the character application object’s Color Map attribute. |
TTA_Columns |
Corresponds to the character application object’s Window
Size: Columns attribute. |
TTA_Compression |
Corresponds to the application object’s Command Compression attribute. This variable can
have the value automatic, on, or off. |
TTA_ContinuousMode |
Corresponds to the application object’s Command Execution attribute.
This variable can have the value automatic, on, or off. |
TTA_ControlCode |
Corresponds to the character
application object’s Escape Sequences attribute. This variable can have the value 7-bit, or 8-bit. |
TTA_Cursor |
Corresponds
to the character application object’s Cursor attribute. This variable can have the value
off, block, or underline. |
TTA_CursorKeyMode |
Corresponds to the character application object’s Cursor Key Codes Modification attribute.
This variable can have the value application, or cursor. |
TTA_DelayedUpdate |
Corresponds to the application object’s Delayed
Updates attribute. |
TTA_DisableCursorSettings |
Corresponds to the Windows application object’s Cursor Settings attribute. |
TTA_DisableCursorShadow |
Corresponds to the Windows
application object’s Cursor Shadow attribute. |
TTA_DisableFullWindowDrag |
Corresponds to the Windows application object’s Full Window Drag attribute. |
TTA_DisableMenuAnimations |
Corresponds
to the Windows application object’s Menu Animations attribute. |
TTA_DisableTheming |
Corresponds to the Windows application object’s Theming
attribute. |
TTA_DisableWallpaper |
Corresponds to the Windows application object’s Desktop Wallpaper attribute. |
TTA_DisplayEnginePage |
Corresponds to the application object’s Emulator
Applet Page attribute.
Note - This attribute is no longer used.
|
TTA_DisplayName |
Corresponds to the user profile’s
Name attribute. |
TTA_Domain |
Corresponds to the application object’s Domain Name attribute. |
TTA_EnableFontSmoothing |
Corresponds to the Windows application object’s Font
Smoothing attribute. |
TTA_EuroMapping |
Corresponds to the application object’s Euro Character attribute. This variable can have
the value iso8859-15, or unicode. |
TTA_FilePath |
Corresponds to the application object’s Application Command attribute. |
TTA_FixedFontSize |
Corresponds to the
character application object’s Font Size: Fixed attribute. |
TTA_FontFamily |
Corresponds to the character application object’s Font Family
attribute. This variable can have the value courier, helvetica, or timesroman. |
TTA_FontSize |
Corresponds to the
character application object’s Font Size attribute. |
TTA_ForegroundColor |
Corresponds to the 3270 or 5250 application object’s Foreground
Color attribute. |
TTA_GraphicsAcceleration |
Corresponds to the application object’s Graphics Acceleration attribute. |
TTA_Height |
Corresponds to the application object’s Window
Size: Height attribute. This variable provides the same information as TTA_AppletHeight. |
TTA_HostLocale |
Corresponds to the
application server object’s Prompt Locale attribute. |
TTA_HostName |
The application server that the login script connects to.
This is chosen by application server load balancing, from those listed on the
Hosting Application Servers tab for the application object. |
TTA_IBMHostName |
Corresponds to the 3270 or 5250
application object’s Server Address attribute. |
TTA_Icon |
Corresponds to the application object’s Icon attribute. |
TTA_InstanceName |
The application session ID. |
TTA_InterlacedImages |
Corresponds
to the application object’s Interlaced Images attribute. This variable can have the value
automatic, on, or off. |
TTA_KeyboardType |
Corresponds to the 3270 or 5250 application object’s Keyboard Type attribute. This
variable can have the value pc, sun4, sun5, and hp. |
TTA_KeymapLock |
Corresponds to the application
object’s Keyboard Map attribute. |
TTA_KeypadMode |
Corresponds to the character application object’s Numpad Codes Modification attribute. This variable
can have the value application, or numeric. |
TTA_Lines |
Corresponds to the character application object’s Window Size:
Lines attribute. |
TTA_LocalAddr |
The IP address of the SGD host. |
TTA_LoginScript |
Corresponds to the application object’s Login
Script attribute. |
TTA_Maximise |
Corresponds to the 3270 or 5250 application object’s Window Size attribute. |
TTA_MiddleMouseTimeout |
Corresponds to
the application object’s Middle Mouse Timeout attribute. |
TTA_NoPrintPrefs |
Corresponds to the Windows application object’s Printer Preference
Caching attribute. |
TTA_ParentName |
The application object’s fully qualified name. This variable provides the same information as
TTA_ApplicationName. |
TTA_PortNumber |
Corresponds to the 3270 or 5250 application object’s Server Port attribute. |
TTA_ProtocolArguments |
Corresponds to the
Windows application object’s Arguments attribute. |
TTA_RemoteAddr |
The IP address of the application server used to run
the application. |
TTA_RemoteAudio |
Corresponds to the Windows application object’s Remote Audio attribute. |
TTA_RequiresDisplayEngine |
Whether or not the
application requires a display engine. |
TTA_ResumeTimeOut |
Corresponds to the application object’s Application Resumability: Timeout attribute. |
TTA_RootColor |
Corresponds to
the application object’s Window Color: Custom Color attribute. |
TTA_RootType |
Corresponds to the application object’s Window Color
attribute. This variable can have the value default, or color. |
TTA_ScrollStyle |
Corresponds to the character application object’s
Scroll Style attribute. This variable can have the value normal, jump, or smooth. |
TTA_SecureConnection |
Corresponds
to the user profile’s Security tab. |
TTA_SessionExit |
Corresponds to the application object’s Session Termination attribute. This variable
can have the value lastclient - Last Client Exit, windowmanager - Window Manager Exit,
windowmanageralone - Only Window Manager Remaining), loginscript - Login Script Exit), loginscript - Login
Script Exit), nowindows - No Visible Windows, and loginscriptnowindows - Login Script exit
or No Visible Windows. |
TTA_SettingsItem |
Corresponds to the 3270 or 5250 application object’s ‘File’ and
‘Settings’ Menus attribute. |
TTA_StatusLine |
Corresponds to the character application object’s Status Line attribute. This variable
can have the value none, indicator, and host writable, standard, or extended. |
TTA_Suspend |
Corresponds to the application
object’s Application Resumability attribute. This variable can have the value never, session (means User Session),
and forever (means Always). |
TTA_TerminalClass |
Corresponds to the character application object’s Emulation Type attribute. This
variable can have the value scoconsole, vt420, or wyse60. |
TTA_TerminalType |
Corresponds to the character application object’s
Terminal Type attribute. |
TTA_TNClose |
Corresponds to the 3270 or 5250 application object’s Connection Closed Action
attribute. This variable can have the value 0 - Prompt User for Action, 1
- Exit Emulator, 2 - Reconnect, and 3 - Close Connection. |
TTA_TopMenuBar |
Corresponds to the
3270 or 5250 application object’s Menu Bar attribute. |
TTA_Transport |
Corresponds to the application object’s Connection Method
attribute. This variable can have the value rexec, telnet, or ssh. The guaranteed variable TTA_CONNECTIONSERVICE
also provides this information. |
TTA_UserName |
The fully qualified name of the user this application session is
for. |
TTA_UserSecurityEquivalent |
Corresponds to the user profile’s User Name attribute. |
TTA_UNIXAUDIO_QUALITY |
Corresponds to the UNIX Audio Quality attribute
on the Global Settings -> Client Device tab in the Administration Console. This variable
can have the value low, medium, and high. |
TTA_UNIXAUDIOPRELOAD |
Corresponds to the X application objects Audio
Redirection Library attribute. |
TTA_ViewHostReply |
Corresponds to the application object’s Keep Launch Connection Open attribute. |
TTA_WebTop |
Corresponds to
the Webtop Theme attribute.
Note - This attribute is no longer used.
|
TTA_Width |
Corresponds to the application
object’s Window Size: Width attribute. This variable provides the same information as TTA_AppletWidth. |
TTA_WinCursor |
Corresponds to
the application object’s Use Windows Cursor attribute.
Note - This attribute is no longer used.
|
TTA_WindowsApplicationServer |
The protocol
used to connect to a Windows application server. This variable can have the
value wincenter, wincentermf - Citrix UNIX Integration Services, merge - SCO Merge, winframe -
Citrix ICA), wts - Microsoft RDP, or none. Only Microsoft RDP is supported. The
other protocols can only be used with legacy SGD Windows application objects. |
TTA_WindowsApplicationSupport |
Corresponds to
the Windows application object’s Local Client Launch attribute. |
TTA_WorkingDir |
Corresponds to the Windows application object’s Working
Directory attribute. |