0 |
ErrOKThe
login script successfully connected to the application server and started the application. |
1 |
ErrApplicationServerResourceFailureThe login
script failed due to a lack of system resources on the application server. Ensure
that the application server is capable of running the application. |
2 |
ErrApplicationServerNoLicenseAvailableNo licenses were available
on the application server. Ensure that the application server has sufficient licenses for the
number of connections you expect to make. |
3 |
ErrFaultInExecutionScriptThe login script contains a syntax
error. Review the login script. |
4 |
|
5 |
ErrApplicationServerLoginIncorrectThe user name and password supplied to the application server were
not accepted. Check that the user name and password are valid on that
application server. |
6 |
ErrApplicationServerPasswordAgedThe user’s password on the application server has expired. Ensure that the user
has a valid password on the application server. To avoid seeing this error,
configure SGD to handle aged passwords. You configure this on the Global Settings
-> Application Authentication tab in the Administration Console. |
7 |
ErrCommandExecutionFailedThe login script successfully logged in
to the application server but could not run the application. Ensure that the application
object’s Application Command attribute contains a valid command. Ensure that the user has write
permissions for the /tmp directory on the application server. |
8 |
ErrApplicationServerConnectionFailedThe login script failed to
log in to the application server. Check that you can log into the
application server manually. |
9 |
ErrApplicationServerEndOfFileOnConnectionThe login script encountered an End of File error (EOF)
on connection to the application server. Investigate why an EOF error is returned. |
10 |
|
12 |
ErrInvalidDesktopSizeThe width
and height defined for a Windows application is not valid. Check the application object’s
Window Size: Width and Window Size: Height attributes. |
14 |
ErrCouldNotPipeThe login script was unable to
create a pipe between the parent and child processes in the Execution Protocol
Engine. This error might indicate that there is not enough memory on the application
server. Check the number of other applications running on the server and increase
size of memory if necessary. |
15 |
ErrCouldNotForkThe login script was unable to fork a
child process in the Execution Protocol Engine. This error might indicate that there is
not enough memory on the application server. Check the number of other applications running
on the server and increase the amount of memory if necessary. |
16 |
ErrScriptReadThe login
script produced an error when trying to read from the script process in
the Execution Protocol Engine. Try to run the application again. If the error
persists, contact Oracle Support. |
17 |
ErrScriptWriteThe login script produced an error when trying to write
to the script process in the Execution Protocol Engine. Try to run the application
again. If the error persists, contact Oracle Support. |
18 |
ErrThirdTierWriteThe login script produced an error
when trying to write to the application server in the Execution Protocol Engine. This
error usually means the connection to the application server was lost. Check the
application server is available and try to run the application again. |
19 |
ErrThirdTierReadThe login script
produced an error when trying to read from the application server in the
Execution Protocol Engine. This error usually means the connection to the application server was
lost. Check the application server is available and try to run the application
again. |
21 |
ErrTransportNotAvailableThe login script was unable to connect to the application server using the
requested connection method method. Check that the application server supports the connection method. Check
that the application server is available. |
22 |
ErrLogFileErrorThis is not an application startup error.
SGD was unable to create a log file for the Protocol Engine Manager. If
the error persists, contact Oracle Support. |
27 |
ErrThirdTierFailureSomething has gone wrong on the application
server. Check that the server is available and that you can run the application
manually. |
30 |
ErrLoginPasswordNotAvailable The login script was unable to supply the application server with a password. This
error usually means the Execution Protocol Engine timeout has been triggered. See Other Timeouts
for details of how to increase the Execution Protocol Engine timeout. |
31 |
ErrRequestNotSupportedThe login script
cannot execute the requested auxiliary commands. Check that the Arguments for Command attribute
for the application object is configured correctly and that the additional commands work on
the application server. |
32 |
ErrRequestNotImplementedThe login script cannot execute the requested operation because it has
not been implemented. If the error persists, contact Oracle Support. |
33 |
ErrUnknownAn error occurred in
the Execution Protocol Engine. Check the log file and try to run the
application again. |
34 |
ErrInternalErrorAn error in the Protocol Engine Manager. Check the log file and
try to run the application again. |
37 |
ErrProtocolEngineDiedThe Protocol Engine process failed. Check the log
file for the process ID of the protocol engine and try running the
application again. If the problem persists, contact Oracle Support. |
43 |
ErrExpectInitialisationFailedSGD was unable to initialize
the Expect interpreter and so the script was not run. Try to run the
application again. If the problem persists, contact Oracle Support. |
44 |
ErrEvalFileFailedThe login script file does
not exist or contains a syntax error that is causing the Expect interpreter
to fail. Check that the login script is in the specified directory. All login
scripts supplied by SGD are stored in the /opt/tarantella/var/serverresources/expect directory. Check the Execution
Protocol Engine error log file for details of any errors with the script. |
45 |
ErrCreateInterpreterFailedSGD
was unable to initialize the Tcl interpreter and so the script was not
run. Try to run the application again. If the error persists, contact Oracle Support. |
46 |
ErrChdirFailedThe
login script failed to change to the directory containing the script. Check the path
to the script. |
47 |
ErrReadErrorThe login script produced an error when trying reading from the
protocol connection between the parent and child processes in the Execution Protocol Engine. Try
to run the application again. If the error persists, contact Oracle Support. |
49 |
ErrEndOfFileThe login
script read an unexpected end of file on a connection. Try to run
the application again. If the error persists, contact Oracle Support. |
51 |
ErrBadMessageThe login script received
an invalid message, probably due to a corruption of the data packet. Try to
run the application again. If the error persists, contact Oracle Support. |
52 |
ErrStaleCookieThe client connected
to the application but the cookie needed for the application startup has expired. Try
to run the application again. If this fails, increase the lifetime of
the cookie. You do this with the following command: $ tarantella config edit --tarantella-config-applaunch-reconnecttimeout seconds The default value is 60
(60 seconds). If the error persists, contact Oracle Support. |
53 |
ErrEatenCookieThe client connected to the
application but the cookie needed for the application startup has already been used,
probably by the user running multiple sessions. Try to run the application again. If
the error persists, contact Oracle Support. |
54 |
ErrDifferentCookieThe client connected to the application but the
cookie supplied does not match the one required for the application startup. Try to
run the application again. If the error persists, contact Oracle Support. |
55 |
ErrLaunchPolicyNotFoundSGD was unable
to find the details needed to run the application. This error might never
occur. Try to run the application again. If this fails, stop the SGD
server, start it again, and then run the application again. If the error
persists, contact Oracle Support. |
56 |
ErrBadLengthThe login script received a message that was not
the correct length, probably due to a corruption of the data packet. Try to
run the application again. If the error persists, contact Oracle Support. |
57 |
ErrInvalidConfigObjectThe configuration data
provided by SGD did not contain all the required information. This error might never
occur. Try to run the application again. If this fails, stop the SGD
server, start it again and then run the application. If the error persists,
contact Oracle Support. |
58 |
ErrSessionCircuitNotFoundThe connection between the protocol engine and the Protocol Engine Manager
was lost. Try to run the application again. If this fails, stop the SGD
server, start it again and then run the application. If the error persists,
contact Oracle Support. |
59 |
ErrExecutionCircuitNotFoundThe connection between the Protocol Engine Manager and the Execution Protocol
Engine was lost. Try to run the application again. If this fails, stop
the SGD server, start it again, and then run the application. If the error
persists, contact Oracle Support. |
61 |
ErrCircuitNotFoundThe Protocol Engine Manager cannot find a circuit (connection). Try
to run the application again. If this fails, stop the SGD server, start
it again and then run the application. If the error persists, contact Oracle
Support. |
62 |
ErrCreateFailedThe create request to the protocol engine failed and SGD was unable to
run the application. The definition of the application is missing some attributes. Check the
log file for details of the missing attributes and correct these errors before
trying to run the application again |
63 |
ErrCompleteThis is not an error. It is
a message from the Execution Protocol Engine to the Protocol Engine Manager to
indicate the launch process was completed. |
65 |
ErrNonZeroConnectresultWhen the SGD Client connected to the protocol
engine, an error occurred. If possible, log out. Otherwise, close the browser and end the
SGD Client processes on the client device. Try to run the application again. |
66 |
ErrUserAbortThis
is not an error. The user canceled the application launch. |
67 |
ErrClientEndOfFileOnConnectionThe connection to
the SGD Client was lost. If possible, log out. Otherwise, close the browser
and end the SGD Client processes on the client device. Try to run
the application again. |
68 |
ErrNothingToDoThis is not an error. This message indicates that the launch request
sent to the Protocol Engine Manager does not require any protocol engines. |
71 |
ErrIoErrorThe login
script was unable to write to stderr. Try to run the application again.
If the error persists, contact Oracle Support. |
73 |
ErrTscLicenseErrorThere are not enough Windows Terminal Services
licenses available to be able to run the application. Increase the number of Windows
Terminal Services licenses. |